5. Rotate Back Focus Adjustment until the optimum focus is achieved.
6. Tighten Back focus Adjustment Lock Screw again.
7. Trim the focus precisely at lens if necessary.
Setting for lenses with a variable focal distance (zoom):
If the focus changes as the focal distance changes, please proceed as follows.
1. Point the camera at an object with sufficient contrast at a distance of approximately 2 meters
2. Open the iris on the lens
3. Set the maximum focal distance (Tele) at the lens
4. Set the optimum focus with the focus ring
5. Set the smallest focal distance (wide angle)
6. Loosen Back focus Adjustment Lock. Screw one~two turns on the camera with the industrial “+” driver
7. Adjust Back Focus Adjustment until the optimum focus is achieved. Steps 3,4,5 and 7 may need to be
repeated several times to obtain the best results
8. Tighten Back focus Adjustment Lock Screw again
5.3. Installation
The camera has a 1/4” thread insert on its top and bottom side for mounting the camera to a tripod, wall
or ceiling with a corresponding mount.
5.4 Commissioning
First, connect the power supply to the power terminal on the rear panel of camera
Second, plug the power adaptor to the main supply
Power indicator LED will be lit
• The camera is ready for operation
5.5. Power Supply Connections
The camera can work with either 24VAC or 12VDC, dual voltage power. It does NOT require the
polarity-matched connection for 12VDC supply. Primary and secondary grounds are completely
isolated to avoid the possible ground-loop problems. Its wide operating voltage range of 10.5V-30V
for DC and 12-28.8V for AC gives extra flexibility at the installation.
6. Start up
When the camera is powered properly, it starts up by initializing the internal parameters and the
filter switch mechanism. The filter switch unit repeats IN and OUT at each power up and just
after RESTORE FACTORY SETTINGS.